EDIFACT message guide · Customs and regulatory

REGENT Registration of enterprise

The UN/EDIFACT message used to send legal, administrative and statutory information on the creation, change or cessation of a business activity.

Sent by
Enterprise or its representative
Received by
Registration authority or other administration
Standard
UN/EDIFACT · Batch message
X12 equivalent
No direct equivalent

What is the EDIFACT REGENT message?

REGENT is the UN/EDIFACT registration of enterprise message. The directory defines it as a message designed to transmit legal, administrative and statutory information about the creation, change or cessation of a business activity within an enterprise. It can be exchanged between an enterprise and an authority responsible for registration, and between authorities.

Registration data, such as legal form, address, activity codes and officers, is needed by trade registers, tax and social security administrations. Exchanging it electronically lets one registration reach several administrations.

How the EDIFACT REGENT message worksDiagram of the UN/EDIFACT REGENT Registration of enterprise message. Enterprise or its representative sends it to registration authority or other administration. It usually starts the exchange. Inside the UNB and UNH envelopes, the directory D.21A requires, in the start of message: BGM (Beginning of message) and body and segment groups: the required SG1 loop with PNA (Party identification), the required SG4 loop with EVE (Event) and the required SG5 loop with DSI (Data set identification) and the required SG6 loop with EVE (Event) and the required SG7 loop with REL (Relationship). 8 conditional segment groups are listed by their trigger segment.How the EDIFACT REGENT message worksRegistration of enterprise: who sends it, where it fits and what the directory marks mandatory1 WHERE IT FITSUSUALLY FOLLOWSStarts the exchangeREGENTSENDEREnterprise or itsrepresentativeRECEIVERRegistration authorityor other administrationCONTRL syntax report back, if agreedUSUALLY FOLLOWED BYNo business reply expected2 WHAT DIRECTORY D.21A REQUIRESInterchange: sender and recipient IDsUNB … UNZMessage REGENTUNH … UNTSTART OF MESSAGEBGMBeginning of messageBODY AND SEGMENT GROUPSMandatory group SG1 · repeats up to 99PNAParty identificationMandatory group SG4 · repeats up to 99EVEEvent+ required SG5 (DSI) and 8 conditional groups, starting with:DOCMOAATTTAXEMPICDBlue box: mandatory segment group. Conditional groups are listed by the trigger segment that starts them; a group is sent only when its data applies.Conditional segments outside groups are not drawn.Structure: mandatory segments and groups in the UN/EDIFACT directory D.21A listing for REGENT. Your trading partner's implementation guide adds itsown requirements.
How the EDIFACT REGENT message worksDiagram of the UN/EDIFACT REGENT Registration of enterprise message. Enterprise or its representative sends it to registration authority or other administration. It usually starts the exchange. Inside the UNB and UNH envelopes, the directory D.21A requires, in the start of message: BGM (Beginning of message) and body and segment groups: the required SG1 loop with PNA (Party identification), the required SG4 loop with EVE (Event) and the required SG5 loop with DSI (Data set identification) and the required SG6 loop with EVE (Event) and the required SG7 loop with REL (Relationship). 8 conditional segment groups are listed by their trigger segment.How the EDIFACT REGENTmessage worksRegistration of enterprise: who sends it, whereit fits and what the directory marks mandatory1 WHERE IT FITSUSUALLY FOLLOWSStarts the exchangeREGENTSENDEREnterprise or itsrepresentativeRECEIVERRegistrationauthority orotheradministrationCONTRL syntax report back, if agreedUSUALLY FOLLOWED BYNo business reply expected2 WHAT DIRECTORY D.21A REQUIRESInterchange: sender and recipient IDs(UNB … UNZ)Message REGENT (UNH … UNT)START OF MESSAGEBGMBeginning of messageBODY AND SEGMENT GROUPSMandatory group SG1 · repeats upto 99PNAParty identificationMandatory group SG4 · repeats upto 99EVEEvent+ required SG5 (DSI) and 8 conditionalgroups, starting with:DOCMOAATTTAXEMPICDBlue box: mandatory segment group. Conditionalgroups are listed by the trigger segment thatstarts them; a group is sent only when its dataapplies. Conditional segments outside groups arenot drawn.Structure: mandatory segments and groups in theUN/EDIFACT directory D.21A listing for REGENT.Your trading partner's implementation guide adds itsown requirements.

How to read this diagram: the top row shows who sends REGENT, to whom, and which messages usually come before and after it. The lower part shows what the directory D.21A itself requires: the envelopes around REGENT and the segments and segment groups it marks mandatory. Conditional groups are listed by their trigger segment rather than drawn in full. This is the directory's minimum, not a trading partner's requirement: a message implementation guide, such as an industry subset or a partner’s own guide, usually makes some conditional groups mandatory, restricts the codes and may use an older directory.

Expand diagram Download SVG

When it is used

  • Registering a new business activity
  • Reporting changes such as address or legal form
  • Notifying cessation of an activity

Where it fits in the message flow

This message REGENT Registration of enterprise

No other message routinely comes directly before or after REGENT; it is exchanged when the business event occurs. If the partners agree, the receiver confirms each interchange with a CONTRL syntax and service report.

Structure

Mandatory segments in REGENT (directory D.21A)

In UN/EDIFACT directory D.21A, the REGENT message has 71 segment positions arranged in 14 segment groups. These are the segments and segment groups marked mandatory at message level, in order; a mandatory group is shown with the segment that starts it. Segments inside conditional groups are needed only when the group is used. This is the directory’s requirement, not your trading partner’s: each partner’s message implementation guide names the directory it uses, often an older one such as D.96A or D.01B where the structure can differ, makes some conditional segments mandatory and restricts the codes.

  • UNH
  • BGM
  • SG1 (PNA)
  • SG4 (EVE)
  • SG5 (DSI)
  • UNT

Practical example

REGENT in practice

A company opens a new branch. Its formalities agent sends the registration authority a REGENT with the branch address, activity code, start date and manager. The authority records the branch and passes the information to the tax and social security administrations.

Implementation

Implementation considerations for REGENT

  • Check which administrations accept REGENT and which require portals.
  • Use official activity classification codes.
  • Report changes within statutory deadlines.
  • Keep confirmations as proof of registration.

Related messages

Related customs and regulatory messages

All 14 customs and regulatory messages

Need help with REGENT?